Drug Test Collection Process


Drug Test Process

  1. Arriving at the Collection Site

    • The collector requests the donor to present photo identification.
    • If the donor’s identity cannot be established, the collector must not proceed with the collection.
    • The collector must provide identification if requested by the donor.
    • The collector must inform the donor that, once the collection procedure has begun, the donor must remain at the collection site (i.e., in an area designated by the collector) until the collection is complete and that failure to follow these instructions will be reported as a refusal to test.
    • This includes the wait period (i.e., up to 3 hours) if needed to provide a sufficient specimen.
  2. Preliminary Steps in the Urine Collection Procedure

    • The collector must take the following steps before beginning a urine specimen collection:
      • When the donor arrives at the collection site, the collector should begin the collection procedure without undue delay.
    • The collector must deter the dilution or substitution of a specimen at the collection site by:​
      • Placing a toilet bluing agent in a toilet bowl or toilet tank, so the reservoir of water in the toilet bowl always remains blue.
    Image
    Photo of toilet with bluing agent.
  3. Storing Unnecessary Items

    • The collector asks the donor to remove any unnecessary outer garments (e.g., coat, jacket) that might conceal items or substances that could be used to adulterate or substitute the urine specimen.
    • The collector must ensure that all personal belongings remain with the outer garments.
    • The donor may retain the donor’s wallet.
    • The donor is not required to remove any items worn for faith-based reasons. These items are still required to be searched.
    • The collector asks the donor to empty the donor’s pockets and display the contents to ensure no items are present that could be used to adulterate or substitute the specimen.
    Image
    Photo of locker.
  4. Completing the CCF

    • The collector explains the basic collection procedure to the donor.
    •  The collector provides the instructions for completing the Federal Drug Testing Custody and Control Form (CCF) for the donor’s review and informs the donor that the instructions are available upon request.
    • The collector answers any reasonable and appropriate questions the donor may have regarding the collection procedure.

    Instructions for Completing the Federal Drug Testing Custody and Control Form (CCF) for Urine Specimen Collection(link is external)

    Image
    Sample CCF.
  5. Washing Hands

    The collector shall instruct the donor to wash and dry the donor’s hands prior to urination.

    Image
    Photo of sink.
  6. Selecting Collection Container

    The collector will provide, or the donor may select a specimen collection container that is clean, unused, wrapped/sealed in original packaging.

    The specimen collection container package will be opened in view of the donor.

    Image
    Photo of collection cup.
  7. Providing/Receiving Instructions

    1. The collector instructs the donor to provide the specimen in the privacy of a stall or otherwise partitioned area that allows for individual privacy.
    2. The collector directs the donor to provide a specimen of at least 45 mL, to not flush the toilet, and to return with the specimen as soon as the donor has completed the void.
      * The collector may set a reasonable time limit for specimen collection
    3. The collector notes any unusual behavior or appearance of the donor on the Federal CCF.
    4. If the collector detects any conduct that clearly indicates an attempt to tamper with a specimen, the collector must report a refusal to test.

    • After providing the specimen, the donor gives the specimen collection container to the collector.
    • Both the donor and the collector must always keep the specimen container in view until the collector seals the specimen bottles.
    • After the donor has given the specimen to the collector, whenever practical, the donor shall be allowed to wash the donor’s hands and the donor may flush the toilet.
    • The collector must measure the temperature of the specimen within 4 minutes of receiving the specimen from the donor.
    • The collector records on the Federal CCF whether the temperature is in the acceptable range of 32°–38°C/90°–100 °F.
    Image
    Photo of collection cup showing temperature of specimen.
  8. Verifying Specimen Bottles

    • The collector, in the presence of the donor, pours the urine from the collection container into two specimen bottles to be labeled ‘‘A’’ and ‘‘B’’. The collector pours at least 30 mL of urine into Bottle A and at least 15 mL into Bottle B and caps each bottle.
    • In the presence of the donor, the collector places a tamper-evident label/seal from the Federal CCF over each specimen bottle cap.
    • The collector records the date of the collection on the tamper-evident labels/seals.
    • The collector instructs the donor to initial the tamper-evident labels/seals on each specimen bottle.
    • If the donor refuses to initial the labels/seals, the collector notes the refusal on the Federal CCF and continues with the collection process.
    • The collector must ensure that all required information is included on the Federal CCF.
    Image
    Photo of two specimen bottles.
    Image
    Photo of two specimen bottles.
  9. Certifying Specimen/Collection

    1. The collector asks the donor to read and sign a statement on the Federal CCF certifying that the specimens identified were collected from the donor.
    2. The collector signs and prints their name on the Federal CCF, completes the Federal CCF, and distributes the copies of the Federal CCF as required.
    3. The collector seals the specimens (Bottle A and Bottle B) in a package.
    4. If the specimen and Federal CCF are not immediately transported to an HHS-certified laboratory or IITF, they must remain under direct control of the collector or be appropriately secured under proper specimen storage conditions until transported.
    5. The collector must discard any urine left over in the collection container after both specimen bottles have been appropriately filled and sealed.